HPI is currently affected by the Covid-19 lockdown in South Africa.
Our administrative staff and the manufacturing ability are currently closed. Our new business, engineering and maintenance teams are operating within the limits of the lockdown.
HPI will attend to emergency breakdowns.
For any emergencies please contact or whatsapp Johan Coetsee on 083-677-0896 or email johan.coetsee@heatpump.co.za.
Stay safe, stay strong and stay at home.
Follow this link to the official SA Government coronavirus website: www.sacoronavirus.co.za
Model | TRTP 295 |
Reference | |
Supply Air Volume l/s | 12000 |
Ext. Static Pa | 250 |
Fan Static Pa | 600 |
Fan Type | BCC 800 |
Fan Motor kW | 15 |
Ambient °C | 35°C DB |
On coil °C DB / °C WB °C | 24°C DB/18°C WB |
Supply air °C DB / °C WB °C | 10°DB/9°C WB |
Compressor Capacity KW | 8x 36kW |
Coil air volume L/s | 12000 |
Total Cooling kW | 295 |
Altitude masl | Sea level |
Stages | 4 |
Refrigerant | R 22 |
Electric heating kW | 15 |
Humidifier Kg/hr | 0 |
Essential Power supply A | 35A 380Vac |
Non-Essential Power supply A | 190A 380Vac |
Filter Media | EU 2-stage |
Filter quan / size | 16 600x600 |
Length / Depth mm | 4 400 |
Width mm | 2 900 |
Height mm | 4 400 |
Condenser Air l/s | 36 000 l/s (Axial fans) |
Model TRP EC | 95 |
105 |
115 |
125 |
135 |
145 |
155 |
165 |
170 |
180 |
190 |
|
Evaporative Condenser VXC | 30 |
30 |
30 |
38 |
38 |
46 |
46 |
52 |
52 |
65 |
65 |
|
Nominal Cooling Capacity |
kW |
96 |
105 |
115 |
124 |
134 |
144 |
153 |
163 |
172 |
182 |
192 |
Supply Air Volume |
m/s |
5 |
5.5 |
6 |
6.5 |
7 |
7.5 |
8 |
8.5 |
9 |
9.5 |
10 |
|
|
Heating to customer specs from 20kW to 140kW |
||||||||||
Unit Dimensions |
|
Units supplied to customer specs. The following table gives examples of dimensions applicable to standard loads, but these may be tailored to suit |
||||||||||
Unit Length/Depth |
|
3300 |
3400 |
3400 |
3600 |
3600 |
3700 |
3700 |
3750 |
3750 |
3800 |
3800 |
Unit Width |
|
2000 |
2000 |
2200 |
2200 |
2200 |
2300 |
2400 |
2400 |
2400 |
2700 |
2700 |
Unit Height |
|
2000 |
2000 |
2000 |
2000 |
2200 |
2200 |
2230 |
2230 |
2230 |
2180 |
2180 |
Operating Mass |
Kg |
3788 |
3890 |
3950 |
4025 |
4025 |
4262 |
4262 |
4282 |
4282 |
4519 |
4519 |
Gross Mass (shipping) |
Kg |
3488 |
3590 |
3650 |
3725 |
3725 |
3962 |
3962 |
3982 |
3982 |
4119 |
4119 |
Full load current |
A |
76 |
80 |
86 |
92 |
100 |
110 |
116 |
122 |
138 |
146 |
154 |
Supply fan diameter |
mm |
500 |
560 |
630 |
630 |
630 |
710 |
710 |
710 |
710 |
800 |
800 |
Capacities and ratings based on 26°C DB/18°C WB on coil & 12.5°C DB/12.0°C WB off coil at sea level. Power supply: 380/50/3 4-wire
Model TRTP | 215 |
230 |
250 |
270 |
290 |
310 |
330 |
350 |
365 |
385 |
405 |
|
Nominal Cooling Capacity |
KW |
212 |
231 |
250 |
269 |
289 |
308 |
327 |
347 |
366 |
385 |
405 |
Supply Air Volume |
m/s |
11 |
12 |
13 |
14 |
15 |
16 |
17 |
18 |
19 |
20 |
21 |
|
|
Heating to customer specs from 20kW to 140kW |
||||||||||
Unit Dimensions |
|
Units supplied to customer specs. The following table gives examples of dimensions applicable to standard loadings, but these may be tailored to suit |
||||||||||
Unit Height |
A |
2130 |
2550 |
2750 |
2750 |
2880 |
2700 |
2600 |
2700 |
2770 |
2770 |
2770 |
Unit Length/Depth |
F |
4140 |
4300 |
4300 |
4500 |
4700 |
5500 |
5500 |
5600 |
5600 |
5600 |
5600 |
Condenser Height |
G |
1250 |
1250 |
1250 |
1250 |
1250 |
1250 |
1250 |
1250 |
1250 |
1250 |
1250 |
Unit Width |
H |
2900 |
2800 |
2800 |
2800 |
2880 |
2800 |
2600 |
2800 |
2800 |
2800 |
2800 |
Total Height |
M |
3380 |
3800 |
4000 |
4000 |
4130 |
4050 |
4050 |
4050 |
4050 |
4050 |
4050 |
Condenser Width |
N |
2134 |
2134 |
2134 |
2134 |
2220 |
2220 |
2220 |
2500 |
2500 |
2500 |
2500 |
Operating Mass |
Kg |
3340 |
3596 |
3852 |
4073 |
4162 |
4418 |
4674 |
4899 |
5155 |
5411 |
5667 |
Gross Mass (shipping) |
Kg |
2840 |
3096 |
3352 |
3573 |
3662 |
3918 |
4174 |
4399 |
4655 |
4911 |
5167 |
Full load current |
A |
195 |
211 |
240 |
268 |
274 |
279 |
285 |
306 |
319 |
342 |
363 |
Supply fan diameter |
Mm |
800 |
900 |
900 |
900 |
1000 |
1000 |
1000 |
1000 |
1000 |
1000 |
1000 |
Model TRTP | 95 |
105 |
115 |
125 |
135 |
145 |
155 |
165 |
175 |
185 |
195 |
|
Nominal Cooling Capacity |
KW |
96 |
106 |
116 |
125 |
134 |
143 |
154 |
163 |
173 |
183 |
192 |
Supply Air Volume |
m/s |
5 |
5.5 |
6 |
6.5 |
7 |
7.5 |
8 |
8.5 |
9 |
9.5 |
10 |
|
|
Heating to customer specs from 20kW to 140kW |
||||||||||
Unit Dimensions |
Units supplied to customer specs. The following table gives examples of dimensions applicable to standard loadings, but these may be tailored to suit |
|||||||||||
Unit Height |
|
2000 |
2000 |
2000 |
2000 |
2200 |
2200 |
2230 |
2230 |
2230 |
2180 |
2180 |
Unit Length/Depth |
|
3300 |
3400 |
3400 |
3600 |
3600 |
3700 |
3700 |
3750 |
3750 |
3800 |
3800 |
Condenser Height |
|
1150 |
1150 |
1250 |
1250 |
1250 |
1250 |
1250 |
1250 |
1250 |
1250 |
1250 |
Unit Width |
|
2000 |
2000 |
2200 |
2200 |
2200 |
2300 |
2400 |
2400 |
2400 |
2700 |
2700 |
Total Height |
|
3150 |
3150 |
3250 |
3250 |
3450 |
3450 |
3480 |
3480 |
3480 |
3430 |
3430 |
Condenser Width |
|
1624 |
1676 |
1865 |
1865 |
2050 |
2050 |
2050 |
2134 |
2134 |
2134 |
2134 |
Operating Mass |
Kg |
1604 |
1701 |
1857 |
1957 |
1991 |
2138 |
2294 |
2450 |
2706 |
2962 |
3218 |
Gross Mass (shipping) |
Kg |
1204 |
1301 |
1457 |
1557 |
1591 |
1738 |
1894 |
2050 |
2306 |
2562 |
2818 |
Full load current |
A |
100 |
103 |
107 |
112 |
115 |
126 |
137 |
155 |
163 |
171 |
183 |
Supply fan diameter |
Mm |
500 |
560 |
630 |
630 |
630 |
710 |
710 |
710 |
710 |
800 |
800 |
Model TRTP | 215 |
230 |
250 |
270 |
290 |
310 |
330 |
350 |
365 |
385 |
405 |
|
Nominal Cooling Capacity |
KW |
212 |
231 |
250 |
269 |
289 |
308 |
327 |
347 |
366 |
385 |
405 |
Supply Air Volume |
m/s |
11 |
12 |
13 |
14 |
15 |
16 |
17 |
18 |
19 |
20 |
21 |
|
|
Heating to customer specs from 20kW to 140kW |
||||||||||
Unit Dimensions |
|
Units supplied to customer specs. The following table gives examples of dimensions applicable to standard loadings, but these may be tailored to suit |
||||||||||
Unit Height |
A |
2130 |
2550 |
2750 |
2750 |
2880 |
2700 |
2600 |
2700 |
2770 |
2770 |
2770 |
Unit Length/Depth |
F |
4140 |
4300 |
4300 |
4500 |
4700 |
5500 |
5500 |
5600 |
5600 |
5600 |
5600 |
Condenser Height |
G |
1250 |
1250 |
1250 |
1250 |
1250 |
1250 |
1250 |
1250 |
1250 |
1250 |
1250 |
Unit Width |
H |
2900 |
2800 |
2800 |
2800 |
2880 |
2800 |
2600 |
2800 |
2800 |
2800 |
2800 |
Total Height |
M |
3380 |
3800 |
4000 |
4000 |
4130 |
4050 |
4050 |
4050 |
4050 |
4050 |
4050 |
Condenser Width |
N |
2134 |
2134 |
2134 |
2134 |
2220 |
2220 |
2220 |
2500 |
2500 |
2500 |
2500 |
Operating Mass |
Kg |
3340 |
3596 |
3852 |
4073 |
4162 |
4418 |
4674 |
4899 |
5155 |
5411 |
5667 |
Gross Mass (shipping) |
Kg |
2840 |
3096 |
3352 |
3573 |
3662 |
3918 |
4174 |
4399 |
4655 |
4911 |
5167 |
Full load current |
A |
195 |
211 |
240 |
268 |
274 |
279 |
285 |
306 |
319 |
342 |
363 |
Supply fan diameter |
Mm |
800 |
900 |
900 |
900 |
1000 |
1000 |
1000 |
1000 |
1000 |
1000 |
1000 |
|
|
|
|
|
|
|
|
|
|
|
|
|